COMMON WEAKNESS ENUMERATIONDraft

CWE-1320

Improper Protection for Outbound Error Messages and Alert Signals

Untrusted agents can disable alerts about signal conditions exceeding limits or the response mechanism that handles such alerts.

Abstraction

Base

Structure

Simple

Likelihood of Exploit

Medium

Understand the problem

What is the problem?

Untrusted agents can disable alerts about signal conditions exceeding limits or the response mechanism that handles such alerts.

Extended description

Hardware sensors are used to detect whether a device is operating within design limits. The threshold values for these limits are set by hardware fuses or trusted software such as a BIOS. Modification of these limits may be protected by hardware mechanisms. When device sensors detect out of bound conditions, alert signals may be generated for remedial action, which may take the form of device shutdown or throttling. Warning signals that are not properly secured may be disabled or used to generate spurious alerts, causing degraded performance or denial-of-service (DoS). These alerts may be masked by untrusted software. Examples of these alerts involve thermal and power sensor alerts.

Root cause

How and when does the problem arise?

Lifecycle phase

Architecture and Design

Lifecycle phase

Implementation

Risk

What does successful exploitation lead to?

DoS: InstabilityDoS: Crash, Exit, or RestartReduce ReliabilityUnexpected State

Affected security scopes: Availability

Defence

How is it prevented and fixed?

Architecture and Design

Architecture and design approach

Detail
Alert signals generated by critical events should be protected from access by untrusted agents. Only hardware or trusted firmware modules should be able to alter the alert configuration.